Système de chauffage indépendant au gaz: Maîtriser 14 Composants stratégiques pour une assurance thermique dans l’Arctique sans ralenti
Le Système de chauffage indépendant au gaz is a mission-critical auxiliary thermal unit for the Camion-benne FAW CA3250P66K24L1TE5Z, ensuring thermal readiness without engine idling. Designed specifically for the Russian Arctic, this air-heating system draws fuel to provide instant, dry heat to the cab and defrost the windshield. Le Système de chauffage indépendant au gaz dramatically reduces fuel consumption during rest periods and guarantees a safe, warm environment for the operator, fulfilling essential safety and operational requirements in temperatures well below freezing.
Système de chauffage indépendant au gaz (For The Entire Vehicle)
| Non. |
Numéro de pièce |
Nom de la pièce |
Quantité |
| 1 |
8115570-13UN |
Oil Extraction Head Assembly |
1 |
| 2 |
8115596-B82 |
Standard Soft Connection |
3 |
| 3 |
8115595-B82 |
Serrer |
7 |
| 4 |
8115580-81U |
Ensemble de pompe à huile |
1 |
| 5 |
8115585-81U |
Oil Pump Fixing Bracket Assembly |
1 |
| 6 |
8115640-72C |
Oil Pump Wiring Harness Assembly – Vehicle |
1 |
| 7 |
8115562-72C |
Fuel Pipe B |
1 |
| 8 |
CQ1460835 |
Boulon combiné |
1 |
| 9 |
Q40208 |
Grande laveuse |
1 |
| 10 |
CQ34008 |
Écrou hexagonal |
1 |
| 11 |
T67427946 |
Bande en plastique |
6 |
| 12 |
8115561-13UN |
Fuel Pipe A |
1 |
| 13 |
8115596-13UN |
Special Soft Connection |
1 |
| 14 |
8115595-13UN |
Serrer – Special Soft Connection |
1 |
Système de chauffage indépendant au gaz (Taxi)
| Non. |
Numéro de pièce |
Nom de la pièce |
Quantité |
| 1 |
8115631-B82 |
Tuyau d'admission |
1 |
| 2 |
8115621AB96 |
Exhaust Pipe |
1 |
| 3 |
8115625-B82 |
Exhaust Pipe Fixing Clamp Assembly |
1 |
| 4 |
CQ67630B |
Hose Clip B Type with Worm Drive |
5 |
| 5 |
8115596-B82 |
Standard Soft Connection |
1 |
| 6 |
8115595-B82 |
Serrer |
2 |
| 7 |
8115561-B82 |
Fuel Pipe |
1 |
| 8 |
8115645-B82 |
Oil/Fuel Pipe Wiring Harness Assembly – Taxi |
1 |
| 9 |
T67427946 |
Bande en plastique |
2 |
| 10 |
8115627-B82 |
Exhaust Pipe Clip |
1 |
| 11 |
8115656-B82 |
Support |
1 |
| 12 |
CQ1460616 |
Boulon combiné |
2 |
| 13 |
CQ34006 |
Écrou hexagonal |
5 |
| 14 |
3724012-A01 |
Cable Tie II |
2 |
Système de chauffage indépendant au gaz (Taxi)2
| Non. |
Numéro de pièce |
Nom de la pièce |
Quantité |
| 1 |
8115505-D04 |
Highland Heater Assembly |
1 |
| 2 |
8115551-B82 |
Sealing Gasket |
1 |
| 3 |
8115552-B82 |
Intake Port Protection Cover |
1 |
| 4 |
8115601AB96 |
Heat Resistant Pipe A |
1 |
| 5 |
8115604-B82 |
T-Shaped Three-Way Connector |
1 |
| 6 |
8115602AB96 |
Heat Resistant Pipe B |
1 |
| 7 |
8115603AB96 |
Heat Resistant Pipe C |
1 |
| 8 |
8115611-B82 |
Air Outlet Base |
2 |
| 9 |
8115612-B82 |
Air Outlet Grille |
1 |
| 10 |
8115650-B82 |
Temperature Control Switch Assembly |
1 |
| 11 |
8115640-D04 |
Heater Main Line Harness Assembly |
1 |
| 12 |
CQ67670B |
Hose Clip B Type with Worm Drive |
6 |
| 13 |
CQ2713513 |
Cross Recessed Pan Head Self-Tapping Screw |
6 |
| 14 |
CQ34006 |
Écrou hexagonal |
5 |
| 15 |
Q40106 |
Machine à laver |
4 |
| 16 |
8115551AB96 |
Sealing Gasket |
1 |
Combustion and Air Management Cores
The functionality of the Système de chauffage indépendant au gaz hinges on the management of air and exhaust gases. Le Tuyau d'admission (Partie no. 8115631-B82) draws fresh, oxygen-rich air into the burner’s combustion chamber. This air must be clean to ensure efficient, soot-free combustion, vital for the long-term health of the heat exchanger core. The rigid structure of the Tuyau d'admission prevents collapse under vacuum or strong crosswinds, guaranteeing the Système de chauffage indépendant au gaz has a constant supply of air.
Combustion products are safely expelled via the Exhaust Pipe (Partie no. 8115621AB96). This pipe must be completely leak-proof to prevent toxic fumes from entering the cab or interfering with the clean heat exchange process. Le matériel du Exhaust Pipe is high-grade stainless steel or aluminum, selected for its resistance to high temperatures and the corrosive, acidic condensation common in exhaust lines. This safety feature is critical for the Système de chauffage indépendant au gaz, ensuring driver safety during long rest periods when the main engine is off.
Securing the exhaust line is the Exhaust Pipe Fixing Clamp Assembly (Partie no. 8115625-B82). This clamp provides a rigid, vibration-resistant mount for the pipe, preventing it from rattling against the chassis. Further protection is offered by the Exhaust Pipe Clip (Partie no. 8115627-B82), which ensures proper routing and thermal spacing. The correct mounting of the Exhaust Pipe is essential for maintaining the heat separation required for the safe and quiet operation of the Système de chauffage indépendant au gaz.
Fuel and Electrical Interface Integrity
The connection between the main fuel system and the heater unit is managed by the Standard Soft Connection (Partie no. 8115596-B82). This flexible polymer component isolates the heater assembly from the severe chassis vibration of the CA3250 dump truck. Without this soft connection, the rigid fuel line components would quickly fatigue and leak. Le Standard Soft Connection est garanti par le Serrer (Partie no. 8115595-B82), which provides the necessary radial compression to ensure a leak-proof seal under constant pressure and vibration.
The fuel lines themselves, comme le Fuel Pipe (Partie no. 8115561-B82), must be chemically resistant to diesel fuel and structurally robust against cold cracking. Ce Fuel Pipe material specification ensures flexibility at sub-zero temperatures. Electrical power and control signals are transmitted via the Oil/Fuel Pipe Wiring Harness Assembly – Taxi (Partie no. 8115645-B82). This harness features specialized insulation that is highly resistant to both abrasion and cold cracking, protecting the electrical connections of the Système de chauffage indépendant au gaz.
The secure routing of the harness and fuel lines is critical, utilizing the Bande en plastique (Partie no. T67427946) et Cable Tie II (Partie no. 3724012-A01) to anchor the wires away from heat sources and sharp edges. This prevents chafing, which could lead to a dangerous short circuit or fuel leak, preserving the operational integrity of the Système de chauffage indépendant au gaz. The integrity of this harness is paramount; a short circuit could disable the heater in life-threatening temperatures.
Mounting Hardware and Clamp Security
The structural mounting of the heater is provided by the Support (Partie no. 8115656-B82). This component ensures the burner remains correctly oriented and stable during operation. Le Support is secured with specialized fasteners like the Boulon combiné (Partie no. CQ1460616), which features an anti-vibration locking mechanism to maintain the mounting rigidity. This is a necessity for the safe and precise operation of the Système de chauffage indépendant au gaz burner and blower fan.
The numerous connection points require robust clamping, utilizing the Hose Clip B Type with Worm Drive (Partie no. CQ67630B). These clips provide continuous, adjustable radial compression, which is crucial for forming an airtight seal on the flexible components and preventing detachment during temperature extremes. The worm drive design allows for precision tightening without cutting into the pipe material, preserving its longevity and the reliability of the Système de chauffage indépendant au gaz.
The mounting hardware includes the Écrou hexagonal (Partie no. CQ34006), which is corrosion-resistant. This is vital as the heater is mounted in the lower chassis areas exposed to road salts and moisture. The resistance of the Écrou hexagonal et Boulon combiné to seizing ensures that the Support and other components can be easily removed and serviced, maintaining the crucial efficiency of the Système de chauffage indépendant au gaz throughout the CA3250 dump truck’s service life.
Maintenance and System Reliability
Entretien du Système de chauffage indépendant au gaz involves checking the integrity of the exhaust and fuel lines. Le Exhaust Pipe Clip should be inspected for signs of loosening, which can indicate excessive vibration. Le Fuel Pipe and the harness must be checked regularly for abrasion, especially near the mounting points secured by the Bande en plastique. Immediate replacement of a damaged Standard Soft Connection is required to prevent diesel leaks and ensure safety, as this is a common wear point for the Système de chauffage indépendant au gaz.
Le Tuyau d'admission must be checked for blockage, especially after driving through deep snow or mud. A clogged intake restricts the air required for combustion, leading to inefficient burning and excessive carbon buildup in the heater core. Maintaining the cleanliness of the Tuyau d'admission and the structural integrity of the Exhaust Pipe is crucial for maximizing the heater’s efficiency and minimizing toxic emissions. The use of the specific Hose Clip B Type with Worm Drive is also vital for ensuring an effective seal.
The components, comme le Exhaust Pipe Fixing Clamp Assembly et le Support, provide rigid anchors. Utilizing only genuine fasteners, comme le Boulon combiné et Écrou hexagonal, ensures that this auxiliary system remains a reliable safety and cost-saving asset in the highly challenging operating environment of the Russian Arctic. This attention to detail ensures the Système de chauffage indépendant au gaz performs its intended function flawlessly.
Conclusion: Guaranteed Thermal Readiness
Le Système de chauffage indépendant au gaz is a non-negotiable safety feature for the FAW CA3250 dump truck. Its meticulous engineering ensures reliable performance in extreme cold. By integrating the high-temperature Exhaust Pipe with the protective Oil/Fuel Pipe Wiring Harness Assembly – Taxi, FAW guarantees continuous thermal readiness. Le Standard Soft Connection et le Exhaust Pipe Fixing Clamp Assembly maintain the integrity of the fuel and exhaust circuits, preventing failure.
This system, anchored by the Support and secured by corrosion-resistant hardware, ensures that the driver can always return to a warm cab and start a preheated engine. Adhering to the specified components and maintenance protocols ensures the Système de chauffage indépendant au gaz continues to deliver efficiency and safety, allowing operations to proceed smoothly in the harshest environments the Russian North can offer. The secure routing using the Bande en plastique et Cable Tie II is critical for long-term reliability.
Emballage et logistique
Pièces FAW, y compris l'ensemble bloc-cylindres, sont emballés avec soin pour garantir une livraison en toute sécurité. Chaque composant est sécurisé dans des matériaux de protection pour éviter tout dommage pendant le transport. Le réseau logistique garantit des expéditions ponctuelles dans le monde entier, soutenir des opérations de maintenance efficaces. Vous trouverez ci-dessous une image illustrant l'emballage standard des pièces de camion FAW., mettant en valeur l’attention portée aux détails dans la manipulation et le stockage.
Cette approche d'emballage minimise le risque de corrosion ou de dommages causés par les chocs., s'assurer que les pièces comme l'ensemble bloc-cylindres FAW arrivent en parfait état. Les clients peuvent compter sur la logistique de FAW pour une qualité et une fiabilité constantes.