Welcome to this definitive expert analysis of the مجموعة منطق صندوق منصهرات هيكل FAW. This critical component is a primary power distribution and circuit protection hub for the FAW Jiefang CA4251P66K24T1A3E5 6×4 جرار نصف مقطورة ديزل. Unlike smaller, auxiliary fuse boxes, this assembly’s “منطق” is to handle high-amperage inputs directly from the battery and distribute that power safely to major, high-load chassis systems, such as the preheat system.
ال مجموعة منطق صندوق منصهرات هيكل FAW (Main P/N: 3722150-92W-C00) is a centralized, sealed unit that serves as the main protection gateway between the battery and the vehicle’s electrical loads. Its design logic is twofold: أولاً, to protect the vehicle’s expensive wiring harnesses from overcurrent and short-circuit events (preventing fires), and second, to centralize fault-finding by housing all critical high-amperage fuses and relays in one serviceable location.
This in-depth guide is an essential resource for technicians and fleet managers. سنقوم بتفكيك الكل مجموعة منطق صندوق منصهرات هيكل FAW from its main housing down to its smallest Minimum Serviceable Units (وحدات التخزين المتنقلة). We will analyze the structural components, the complete set of high-amperage fuses, the switching relays, and the main power connection lines that define this system.
أساس مجموعة منطق صندوق منصهرات هيكل FAW consists of two primary structural components: the ‘Chassis fuse box assy’ (3722150-92W-C00) and its ‘Chassis fuse box cover’ (3722151-92W-C00).
1. The Box (3722150-92W-C00): This is far more than a simple container. ال “منطق” of this main assembly lies in its internal construction. إنه مصبوب من التأثير العالي, heat-resistant polymer and contains a pre-fabricated internal network of copper busbars. These busbars are the “منطق” of the power distribution, taking the single, high-amperage input from the ‘Battery positive… connection line’ (3724290-92دبليو) and splitting it safely and efficiently to the 15 مآخذ الصمامات و 2 مآخذ التتابع. This solid-state distribution is infinitely more reliable than using individual wires.
2. الغلاف (3722151-92W-C00): This is a critical minimum serviceable unit. إنه “منطق” is sealing. This cover is designed with a heavy-duty gasket (likely silicone or EPDM rubber) that creates a watertight and dust-tight (IP-rated) seal when secured. A failure of this cover (الشقوق, missing gasket) is a primary cause of system failure. It allows water and road salt to enter the مجموعة منطق صندوق منصهرات هيكل FAW, causing corrosion on the fuse legs and relay pins, leading to intermittent power and “ghost” الأعطال الكهربائية.
This section details the most critical Minimum Serviceable Units (وحدات التخزين المتنقلة) داخل مجموعة منطق صندوق منصهرات هيكل FAW. These fuses are the “ذبيحة” عناصر, designed to fail instantly in an overcurrent situation to protect the expensive wiring harness and electronic modules. This box is notable for its high-amperage capacity.
ال “منطق” of a fuse is to be the weak link. The internal metal strip is precisely calibrated to melt and break the circuit if the amperage exceeds its rating, منع حريق كهربائي.
This assembly contains a total of 15 fuses across four different ratings:
1. 5فتيل من نوع بليد (3722011-50): قائمة الأجزاء تدعو إلى اثنين (2) من هؤلاء. These are for very low-power circuits. Their logic is to protect “يتحكم” أو “sensing” دوائر. They are likely used to provide protected power to the low-amperage coil side (دبوس 85/86) of the two relays (3711030-24فرقة 3722110-671) housed within the same box.
2. 10فتيل من نوع بليد (3722012-50): The list specifies three (3) من هؤلاء. These are for standard-duty electrical components. On a chassis, this could include power for marker lights, secondary ECUs, or instrumentation power feeds.
3. 20فتيل من نوع بليد (3722014-50): The box contains three (3) of these heavy-duty fuses. These are for significant loads. One of these is almost certainly paired with the ‘Four-pin relay assy (20أ)’ (3711030-24ب) to power a component like an auxiliary fuel pump, a work light, or a specific electronic module.
4. 30فتيل من نوع بليد (3722017-50): This is the most significant group. ال مجموعة منطق صندوق منصهرات هيكل FAW is populated with seven (7) of these high-amperage fuses. This highlights its role as a primary power distribution center. A 30A fuse is required for major systems. One of these is undoubtedly dedicated to the ‘Preheat electric harness’ (3724295-92دبليو), as glow plug systems have a massive current draw. Other 30A circuits could protect the main ABS/EBS power feed, trailer power, or inverter power.
هؤلاء 15 fuses are the most common service items. A technician can visually inspect them for a broken link and replace them in seconds, restoring function to a dead circuit. هذا هو جوهر “منطق الخدمة” التابع مجموعة منطق صندوق منصهرات هيكل FAW.
ال مجموعة منطق صندوق منصهرات هيكل FAW also contains the “منطق” for controlling circuits, not just protecting them. This is achieved via two plug-in relays, which are both MSUs. A relay is an electromagnetic switch that allows a low-power switch (في الكابينة) to safely control a high-power device.
1. أربعة دبوس التتابع عاصي (20أ) (3711030-24ب): This is a standard, 20-amp-rated automotive relay. It is used to control one of the heavy-duty circuits, such as an auxiliary system. It is plug-and-play and can be easily tested and swapped.
2. التتابع الرئيسي عاصي (3722110-671): This is the most important switching component in the box. ك “Main Relay,” its function is to provide power to multiple circuits *at the same time* when the ignition is turned on. هذا هو “منطق” that ensures chassis systems are only powered when the truck is active, preventing battery drain. A failure of this single relay could disable multiple systems at once.
This final group of components connects the مجموعة منطق صندوق منصهرات هيكل FAW to the vehicle’s electrical system.
Main Power Cables: These are not simple wires; they are heavy-gauge, high-amperage assemblies.
السحابات (CQ1460820, س034008, Q2360612): These are also critical MSUs. "الترباس المختلط".’ (CQ1460820) و "الجوز السداسي."’ (س034008) are used for the main power cable connections. هُم “منطق” is to provide high clamping force and vibration resistance (via a captive washer) for a secure, high-amperage connection. The ‘Cross recessed pan head… screws’ (Q2360612) are used to mount the مجموعة منطق صندوق منصهرات هيكل FAW itself to the chassis frame, ensuring it is secure.
الجدول التالي يوفر كامل, 13-component breakdown for the مجموعة منطق صندوق منصهرات هيكل FAW, including all structural, حماية, and connection components for the FAW CA4251P66K24T1A3E5.
| علامة | الجزء لا. | جزء اسم | كمية |
|---|---|---|---|
| 1 | 3722150-92W-C00 | Chassis fuse box assy (انظر الرسم) | 1 |
| 2 | 3722151-92W-C00 | غطاء صندوق منصهرات الهيكل (انظر الرسم) | 1 |
| 3 | 3711030-24ب | أربعة دبوس التتابع عاصي (20أ) | 1 |
| 4 | 3722011-50 | 5فتيل من نوع بليد | 2 |
| 5 | 3722012-50 | 10فتيل من نوع بليد | 3 |
| 6 | 3722014-50 | 20فتيل من نوع بليد | 3 |
| 7 | 3722017-50 | 30فتيل من نوع بليد | 7 |
| 8 | 3722110-671 | التتابع الرئيسي عاصي | 1 |
| 9 | 3724290-92دبليو | Battery positive pole base plate fuse box connection line assy | 1 |
| 10 | 3724295-92دبليو | Preheat electric harness assy base plate fuse box connection line assy | 1 |
| 11 | CQ1460820 | تركيبة الترباس | 4 |
| 12 | س034008 | مسدس الجوز | 4 |
| 13 | Q2360612 | برغي تركيبة رأس المقلاة المتقاطعة | 4 |
المواصفات ل مجموعة منطق صندوق منصهرات هيكل FAW are defined by its function as the primary high-amperage protection and distribution point for the chassis. It is engineered for extreme durability, weather resistance, and simple serviceability.
| تطبيق المركبة | فاو جيفانغ CA4251P66K24T1A3E5 6×4 جرار |
| مجموعة المكونات | مجموعة منطق صندوق منصهرات هيكل FAW |
| رقم الجزء التجميعي الرئيسي. | 3722150-92W-C00 |
| نوع النظام | Primary Chassis Power Distribution Unit (PDU) |
| جهد النظام | 24في العاصمة (الاسمي) |
| جامعة ولاية ميشيغان (التبديل) | 1x Main relay (3722110-671), 1x 20A relay (3711030-24ب) |
| جامعة ولاية ميشيغان (حماية) | 15x Blade-Type Fuses |
| Fuse Population | 2× 5 أ, 3× 10 أ, 3× 20 أ, 7× 30 أمبير |
| Key Input Cable | Battery Positive… Line (3724290-92دبليو) |
| Key Output Cable | Preheat… Line (3724295-92دبليو) |
| ختم | Gasket-sealed via ‘Chassis fuse box cover’ (3722151-92W-C00) |
| تركيب الأجهزة | 4x Q2360612 (Box); 4x CQ1460820, 4x Q034008 (الكابلات) |
أجزاء فاو, بما في ذلك مجموعة كتلة الأسطوانة, يتم تعبئتها بعناية لضمان الولادة الآمنة. يتم تأمين كل مكون في مواد واقية لمنع الضرر أثناء النقل. تضمن الشبكة اللوجستية الشحنات في الوقت المناسب في جميع أنحاء العالم, دعم عمليات الصيانة الفعالة. فيما يلي صورة توضح العبوة القياسية لقطع غيار شاحنات FAW, إظهار الاهتمام بالتفاصيل في التعامل والتخزين.
يقلل أسلوب التغليف هذا من مخاطر التآكل أو التلف الناتج عن الصدمات, ضمان وصول أجزاء مثل FAW Cylinder Block Assembly في حالة ممتازة. يمكن للعملاء الاعتماد على الخدمات اللوجستية التي تقدمها FAW للحصول على الجودة والموثوقية المتسقة.