Welcome to this definitive expert analysis of the Блок предохранителей шасси FAW в сборе. This critical component is a primary power distribution and circuit protection hub for the FAW Jiefang CA4251P66K24T1A3E5 6×4 дизельный полуприцеп тягач. Unlike smaller, auxiliary fuse boxes, this assembly’s “логика” is to handle high-amperage inputs directly from the battery and distribute that power safely to major, high-load chassis systems, such as the preheat system.
The Блок предохранителей шасси FAW в сборе (Main P/N: 3722150-92W-C00) is a centralized, sealed unit that serves as the main protection gateway between the battery and the vehicle’s electrical loads. Its design logic is twofold: первый, to protect the vehicle’s expensive wiring harnesses from overcurrent and short-circuit events (preventing fires), и второй, to centralize fault-finding by housing all critical high-amperage fuses and relays in one serviceable location.
This in-depth guide is an essential resource for technicians and fleet managers. Мы разберем всю Блок предохранителей шасси FAW в сборе from its main housing down to its smallest Minimum Serviceable Units (МГУ). We will analyze the structural components, the complete set of high-amperage fuses, the switching relays, and the main power connection lines that define this system.
Основа Блок предохранителей шасси FAW в сборе consists of two primary structural components: the ‘Chassis fuse box assy’ (3722150-92W-C00) and its ‘Chassis fuse box cover’ (3722151-92W-C00).
1. The Box (3722150-92W-C00): This is far more than a simple container. The “логика” of this main assembly lies in its internal construction. It is molded from high-impact, heat-resistant polymer and contains a pre-fabricated internal network of copper busbars. These busbars are the “логика” of the power distribution, taking the single, high-amperage input from the ‘Battery positive… connection line’ (3724290-92Вт) and splitting it safely and efficiently to the 15 fuse sockets and 2 relay sockets. This solid-state distribution is infinitely more reliable than using individual wires.
2. The Cover (3722151-92W-C00): This is a critical minimum serviceable unit. Его “логика” is sealing. This cover is designed with a heavy-duty gasket (likely silicone or EPDM rubber) that creates a watertight and dust-tight (IP-rated) seal when secured. A failure of this cover (трещины, missing gasket) is a primary cause of system failure. It allows water and road salt to enter the Блок предохранителей шасси FAW в сборе, causing corrosion on the fuse legs and relay pins, leading to intermittent power and “ghost” электрические неисправности.
This section details the most critical Minimum Serviceable Units (МГУ) в рамках Блок предохранителей шасси FAW в сборе. These fuses are the “жертвенный” компоненты, designed to fail instantly in an overcurrent situation to protect the expensive wiring harness and electronic modules. This box is notable for its high-amperage capacity.
The “логика” of a fuse is to be the weak link. The internal metal strip is precisely calibrated to melt and break the circuit if the amperage exceeds its rating, предотвращение электрического пожара.
This assembly contains a total of 15 fuses across four different ratings:
1. 5A Blade-type fuse (3722011-50): В списке запчастей указано два (2) из этих. These are for very low-power circuits. Their logic is to protect “контроль” или “sensing” схемы. They are likely used to provide protected power to the low-amperage coil side (Приколоть 85/86) of the two relays (3711030-24Группа 3722110-671) housed within the same box.
2. 10A Blade-type fuse (3722012-50): The list specifies three (3) из этих. These are for standard-duty electrical components. On a chassis, this could include power for marker lights, secondary ECUs, or instrumentation power feeds.
3. 20A Blade-type fuse (3722014-50): The box contains three (3) of these heavy-duty fuses. These are for significant loads. One of these is almost certainly paired with the ‘Four-pin relay assy (20А)’ (3711030-24Б) to power a component like an auxiliary fuel pump, a work light, or a specific electronic module.
4. 30A Blade-type fuse (3722017-50): This is the most significant group. The Блок предохранителей шасси FAW в сборе is populated with seven (7) of these high-amperage fuses. This highlights its role as a primary power distribution center. A 30A fuse is required for major systems. One of these is undoubtedly dedicated to the ‘Preheat electric harness’ (3724295-92Вт), as glow plug systems have a massive current draw. Other 30A circuits could protect the main ABS/EBS power feed, trailer power, or inverter power.
Эти 15 fuses are the most common service items. A technician can visually inspect them for a broken link and replace them in seconds, restoring function to a dead circuit. This is the core “сервисная логика” принадлежащий Блок предохранителей шасси FAW в сборе.
The Блок предохранителей шасси FAW в сборе also contains the “логика” for controlling circuits, not just protecting them. This is achieved via two plug-in relays, which are both MSUs. A relay is an electromagnetic switch that allows a low-power switch (в такси) to safely control a high-power device.
1. Four-pin relay assy (20А) (3711030-24Б): This is a standard, 20-amp-rated automotive relay. It is used to control one of the heavy-duty circuits, such as an auxiliary system. It is plug-and-play and can be easily tested and swapped.
2. Main relay assy (3722110-671): This is the most important switching component in the box. Как “Main Relay,” its function is to provide power to multiple circuits *at the same time* when the ignition is turned on. Это “логика” that ensures chassis systems are only powered when the truck is active, preventing battery drain. A failure of this single relay could disable multiple systems at once.
This final group of components connects the Блок предохранителей шасси FAW в сборе to the vehicle’s electrical system.
Main Power Cables: These are not simple wires; they are heavy-gauge, high-amperage assemblies.
Крепежи (CQ1460820, Q034008, Q2360612): These are also critical MSUs. The ‘Combination bolt’ (CQ1460820) и «Шестигранная гайка’ (Q034008) are used for the main power cable connections. Их “логика” is to provide high clamping force and vibration resistance (via a captive washer) for a secure, high-amperage connection. The ‘Cross recessed pan head… винты’ (Q2360612) are used to mount the Блок предохранителей шасси FAW в сборе itself to the chassis frame, ensuring it is secure.
В следующей таблице представлена полная, 13-component breakdown for the Блок предохранителей шасси FAW в сборе, including all structural, защита, and connection components for the FAW CA4251P66K24T1A3E5.
| Отметка | Часть №. | Наименование | Количество |
|---|---|---|---|
| 1 | 3722150-92W-C00 | Chassis fuse box assy (см. рисунок) | 1 |
| 2 | 3722151-92W-C00 | Chassis fuse box cover (см. рисунок) | 1 |
| 3 | 3711030-24Б | Four-pin relay assy (20А) | 1 |
| 4 | 3722011-50 | 5A Blade-type fuse | 2 |
| 5 | 3722012-50 | 10A Blade-type fuse | 3 |
| 6 | 3722014-50 | 20A Blade-type fuse | 3 |
| 7 | 3722017-50 | 30A Blade-type fuse | 7 |
| 8 | 3722110-671 | Main relay assy | 1 |
| 9 | 3724290-92Вт | Соединительная линия блока предохранителей базовой пластины положительного полюса аккумулятора в сборе | 1 |
| 10 | 3724295-92Вт | Предварительный нагрев электропроводки в сборе, опорная пластина, соединительная линия коробки предохранителей в сборе | 1 |
| 11 | CQ1460820 | Комбинированный болт | 4 |
| 12 | Q034008 | Шестигранная гайка | 4 |
| 13 | Q2360612 | Комбинированный винт с крестообразной потайной головкой | 4 |
Технические характеристики Блок предохранителей шасси FAW в сборе are defined by its function as the primary high-amperage protection and distribution point for the chassis. It is engineered for extreme durability, weather resistance, and simple serviceability.
| Приложение для автомобиля | FAW Цзефан CA4251P66K24T1A3E5 6×4 Трактор |
| Группа компонентов | Блок предохранителей шасси FAW в сборе |
| Main Assembly Part No. | 3722150-92W-C00 |
| Тип системы | Primary Chassis Power Distribution Unit (PDU) |
| Системное напряжение | 24В Вашингтоне (Номинальный) |
| МГУ (Switching) | 1x Main relay (3722110-671), 1x 20A relay (3711030-24Б) |
| МГУ (Защита) | 15x Blade-Type Fuses |
| Fuse Population | 2x 5A, 3x 10A, 3x 20A, 7x 30A |
| Key Input Cable | Battery Positive… Line (3724290-92Вт) |
| Key Output Cable | Preheat… Line (3724295-92Вт) |
| Уплотнение | Gasket-sealed via ‘Chassis fuse box cover’ (3722151-92W-C00) |
| Монтажное оборудование | 4x Q2360612 (Box); 4x CQ1460820, 4x Q034008 (Кабели) |
Запчасти ФАВ, включая блок цилиндров в сборе, тщательно упакованы, чтобы обеспечить безопасную доставку. Каждый компонент закреплен защитными материалами для предотвращения повреждений при транспортировке.. Логистическая сеть гарантирует своевременную доставку по всему миру., поддержка эффективных операций по техническому обслуживанию. Ниже приведено изображение, иллюстрирующее стандартную упаковку запчастей для грузовиков FAW., демонстрация внимания к деталям в обращении и хранении.
Такой подход к упаковке сводит к минимуму риск коррозии или ударного повреждения., обеспечение доставки таких деталей, как блок цилиндров FAW в сборе, в идеальном состоянии.. Клиенты могут положиться на логистику FAW для обеспечения стабильного качества и надежности..